| Interval | Action | Tool Required | | :--- | :--- | :--- | | | Wipe external ribbon dust | Lint-free cloth | | Weekly | Clean the platen roller (rubber roller) | Isopropyl alcohol & cloth | | Monthly | Internal compressed air blow-out (low pressure) | Canned air (30 PSI max) | | Every 20 rolls of ribbon | Full printhead alignment check | Manual alignment jig (part # X40-ALIGN) | | Annually | Firmware update & Real-time clock battery check | USB stick + SD card image |