Skip to content

Asme Section Ix Code Book Direct

START | v Select qualified WPS for job (P-No., thickness, position) | v Weld test coupon per WPS | v Perform visual examination (pass/fail) | v Cut test specimens (2 bends + optional macro) | v Perform bend test (guided bend per QW-466) | v Examine bends for discontinuities | v All bends clean? ----NO---> Welder fails → Retrain/Retest | YES | v Complete WPQ form (signatures, date) | v Welder qualified for production